The Crystal EX Ultrapure systems are economy class, multi-purpose, water purification systems.
All Crystal EX Systems produce two types of water : Ultrapure (ISO 3696 Grade 1) and Pure (ISO 3696 Grade 2). Ultrapure water produced by the Crystal EX systems has resistivity 18.2 Mega Ohm*cm (conductivity 0.055 µS/cm). This exceeds requirements of all the relevent standards (ISO 3696 Grade 1, ASTM Type I, CLSI Type I). Purified water is collected in a storage tank. The recirculation system ensures a consistent quality of water, and a low level of organic carbon content (TOC). TOC is <2 ppb for “HPLC” and “Bio” configurations, and 5-10 ppb for the “Trace” configuration.
The dispensing rate of high quality Ultrapure water is 2 L/min.
Pure water produced by Crystal EX systems can be used for labware washing, wet chemistry methods, flame spectrophotometers, etc., Pure water is dispensed directly from the storage tank. The dispensing flow rate of pure water is 4 L/min.
Crystal EX Ultrapure water systems are available in the following configurations:
Application | EX-1001-P Trace | EX-1101-P HPLC | EX-1201-P Bio |
Water Type |
|
|
|
Application |
|
|
|
Display | Monochrome LCD display | Monochrome LCD display | Monochrome LCD display |
Conductivity Sensor | - | - | - |
TOC Monitor | Option | Option | Option |
Connection Possibility to Water Dispensing Unit | No | No | No |
Storage Unit | Water storage tank 'Pro' 30 L w/o multipoint sensor included | ||
Installation | Installation on a laboratory bench |
Purified Water Specifications | Crystal EX Trace | Crystal EX HPLC | Crystal EX BIO |
Grade 1 water resistivity | 18.2 MΩ x cm | 18.2 MΩ x cm | 18.2 MΩ x cm |
Grade 1 water conductivity | 0.055 μS / cm | 0.055 μS / cm | 0.055 μS / cm |
Grade 2 water resistivity | > 10 MΩ x cm | > 10 MΩ x cm | > 10 MΩ x cm |
Grade 2 water conductivity | < 0.1 μS / cm | < 0.1 μS / cm | < 0.1 μS / cm |
Total organic carbon (TOC) level | 5-10 ppb | < 2 ppb | < 2 ppb |
RNase | N/A | N/A | < 0.01 pg/ml |
DNase | N/A | N/A | < 4 pg/ml |
Bacteria | < 1 CFU / ml | < 1 CFU / ml | < 0.1 CFU / ml |
Endotoxins | < 0.15 EU / ml | < 0.15 EU / ml | < 0.001 EU / ml |
Particles > 0.22 µm | < 1 per ml | < 1 per ml | < 1 per ml |
Nominal flow, pure water (to storage tank) | 10 L/h | 10 L/h | 10 L/h |
Nomial dispense flow, pure water | 4 L / min | 4 L / min | 4 L / min |
Deionization module life (standard module) | 1 m3 | 1 m3 | 1 m3 |
Deionization module life (high capacity module) | 3 m3 | 3 m3 | 3 m3 |
Recovery | > 30 % | > 30 % | > 30 % |
Dimensions (W X D X H) cm | 40 X 35 X 55 | 40 X 35 X 55 | 40 X 35 X 55 |
Feed water pressure | 1-4 bar | 1-4 bar | 1-4 bar |
Feed water conductivity | < 1500 μS / cm | < 1500 μS / cm | < 1500 μS / cm |